Gas Meter Room Ventilation Requirements

Any one of the following methods shall be considered sufficient to provide proper ventilation to a room or space in which a gas meter s is installed.
Gas meter room ventilation requirements. The purpose of ventilation in a meter installation housing is to. Gas meter room requirements as per these guidelines and multinet technical standards will be discussed and agreed upon notably regarding civil structural hvac lighting signage service route meter room size venting locations door requirements and location. House domestic and small non domestic meters. Allows any escape of gas to be smelled or otherwise detected by passers by.
The effective vent area should be a minimum of 3 square inches for. The location of the gas meter room shall be on. An opening to the outside air in the wall of such room or space provided the free area of the opening is not less than 30 square inches 19 321 mm 2. This states that bin rooms should.
Meter compartment a room or cupboard specifically designed to house the meter installation n j u g national joint utilities group regulator a device whose function is to control pressure in a gas stream ventilation the movement of air and its replacement with fresh air. Ventilation for bin rooms where can i find the ventilation requirement for a bin room. Gas meter room s must be designed to prevent entrapment of gas. A meter room with a floor area of 10.
Any one of the following methods shall be considered sufficient to provide proper ventilation to a room or space in which a gas meter s is installed. Project start date expected service date and load details for all meters including required pressure for new service for a residential subdivision. The requirements of this standard must be met when a customer houseline is added to an existing gas meter room or gas meter set within a building. Ventilation of bin rooms in blocks of flats should vent any odorous or dense flammable gases that may escape from the waste.
A duct having a cross section area of at least 50 square inches 32 522 mm 2 of free area. Ensure that minor gas leakage does not cause the atmosphere within the housing to become unsafe. For new gas service. Mechanical ventilation to the outside atmosphere is required.
The total effective ventilation area free area shall not be less than 2 of the. A cabinet containing three or fewer residential size meters. 3 0 gas meter and regulator locations continued 3 7 when located inside the building meters shall be located as near as practicable to the point of entrance of the service and where possible the meters shall be located in the cellar or basement unless otherwise. Gas meter and regulator installation requirements.
An opening to the outside air in the wall of such room or space provided the free area of the opening is not less than 30 square inches 19 321 mm 2. The meter room should be able to communicate either with the outside or with an occupied portion of the building.